System

2+ CPU cores

8+ GB RAM

Virtual machine

The OVA file is configured to use 2 cores.

Storage

80+ GB available disk storage

Swarm nodes need to direct syslog logging messages at a dedicated partition on the Platform server.

Clusters that are large or have increased logging loads will require more storage for logging.

OS

Ubuntu Server 16.04 (Xenial)

http://releases.ubuntu.com/xenial/

or

Platform Server OVA Image

Network

Static IP address

Configure a network interface with a static IP address on the managed network before installing Swarm Platform.

Note: If your Platform needs to be installed using Offline Mode if firewall settings prevent Internet access, you will need to install Platform using Offline Mode.

IPMI

Enabled

IPMI 2.0 or newer

To control the power state of managed chassis, Platform uses IPMI (Intelligent Platform Management Interface), a standard for out-of-band (LOM, Lights-Out Management) device management and monitoring using a dedicated management channel.

iDRAC-equipped nodes to be used for Swarm Storage must have the setting Enable IPMI Over LAN  enabled, which allows Platform Server to power the machine and commission the node.

Info

Note

If iDRAC cannot be set to Enable IPMI Over LAN, the chassis needs needs to be manually powered on twice so it can progress through the lifecycle. See Manual Power Control under Deploying Storage, below.

...